Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

DHVE 531da7cb4ec0a43f6814399a Products https://www.vaccumpumpmanufacturer.com
  • 2018-10-10T06:55:04

Digital Thickness Monitor Dinesh high vacuum engineering manufacturer Specifications : Thickness maximum : Transducer limited typically 5000 micro gm/sq.cm. As much as 20, 000 micro gm/sq for well behaved materials (2.0 micro gm/sq.cm= 37 Ang.A). Rate Display: 3 digit LED Thickness display : Automatically varied 0.4 to 5 update/sec. Static thickness resolution : 1 Ang at min update rate Input parameter : Tooling factor, density and acoustic impedance inputs allow readout directly in angstroms. Films no: Allows input parameter for 1 to 100 films to be entered. Tooling factor : 1.0 to 999.9% Film accoustc impedance : 5.000 to 99.99x10-5gm/cm.sec. Shutter control : Dedicated relay. Thickness set point : 0.000 to 990.9% K.Ang. shutter relay closed when displayed thickness equals or exceed set point. Start Control : Zero thickness and open shutter relay Stop Control : Zero thickness and close shutter relay Shutter position indicator : LED `ON` indicates shutter relay activated. Crystal compatibility: 5 or 6 MHz, jumper, jumper selectable. Crystal Holder : Water cooled. Crystal health : % of crystal life remaining 0% of life referenced to a film thickness of 925K.A of Aluminium. Crystal Frequency : 5 or 6 MHz. (Selectable) Output control : Rate of thickness select. Full scale and zero scale O/P useful in calibration recording equipment. Self test : Automatic detection and indication of oscillator failure, power line failure, internal failure Power requirement : 230V AC, 50Hz, 5 Amps contect 9818085534

Digital Thickness Monitor Dinesh high vacuum engineering manufacturer Specifications : Thickness maximum : Transducer limited typically 5000 micro gm/sq.cm. As much as 20, 000 micro gm/sq for well behaved materials (2.0 micro gm/sq.cm= 37 Ang.A). Rate Display: 3 digit LED Thickness display : Automatically varied 0.4 to 5 update/sec. Static thickness resolution : 1 Ang at min update rate Input parameter : Tooling factor, density and acoustic impedance inputs allow readout directly in angstroms. Films no: Allows input parameter for 1 to 100 films to be entered. Tooling factor : 1.0 to 999.9% Film accoustc impedance : 5.000 to 99.99x10-5gm/cm.sec. Shutter control : Dedicated relay. Thickness set point : 0.000 to 990.9% K.Ang. shutter relay closed when displayed thickness equals or exceed set point. Start Control : Zero thickness and open shutter relay Stop Control : Zero thickness and close shutter relay Shutter position indicator : LED `ON` indicates shutter relay activated. Crystal compatibility: 5 or 6 MHz, jumper, jumper selectable. Crystal Holder : Water cooled. Crystal health : % of crystal life remaining 0% of life referenced to a film thickness of 925K.A of Aluminium. Crystal Frequency : 5 or 6 MHz. (Selectable) Output control : Rate of thickness select. Full scale and zero scale O/P useful in calibration recording equipment. Self test : Automatic detection and indication of oscillator failure, power line failure, internal failure Power requirement : 230V AC, 50Hz, 5 Amps contect 9818085534

  • 2018-10-10T06:55:04

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us